banner

Products

Optical Contact Angle Tester Contact Goniometerg Lr

Optical Contact Angle Tester Contact Goniometerg Lr

Optical Contact Angle Tester Contact GoniometerG LR-SDC-100Summy Contact Angle refers to the tangent line of the gas-liq
SHARE

Description

Basic Info.
Model NO. LR-SDC-100
Accuracy Grade 0.5
Load Way 1
Loading Method 1
Display Digital
Control Manual Control
Weight 20kg
Power Source AC220V
Oil Cylinder Position No
Contact Angle Measurement Range 0-180°
Accuracy of Contact Angle Measurement ±0.1°
Maximum Sample Size 10inch
Work Table Size 120mm*150mm
Transport Package Plywood Box
Specification 420× 350× 600mm
Trademark lonroy
Origin China
HS Code 9024800000
Production Capacity 200PCS/Month
Product Description
Optical Contact Angle Tester Contact GoniometerG LR-SDC-100Summy
Contact Angle refers to the tangent line of the gas-liquid interface at the intersection point of gas, liquid and solid. This tangent line has an Angle between the liquid and the solid-liquid boundary. The measurement of Contact Angle is the main method of surface performance detection nowadays.
Standard contact Angle measurement instrument is to use the principle of optical imaging, image contour analysis way to measure the surface contact Angle, wettability, interfacial tension of table, surface energy, such as performance, equipment cost-effective, comprehensive functions, and can meet the demand of conventional measurement, has been widely used in many colleges and universities institutes and enterprises.
Application
Contact Angle measuring instrument is widely used in various industries, in the mobile phone manufacturing, glass manufacturing, surface treatment, material research, chemical and chemical industry, semiconductor manufacturing, paint and ink, electronic circuits, textile fiber, medical biological and other fields, contact Angle measurement has become an important instrument to evaluate the surface performance.
(some test functions need to be completed by purchasing special accessories)
1. Wetting behaviors of liquid on solid surface, such as spreading, infiltration and absorption, etc., static contact Angle was measured by droplet method;
2. Measurement of forward Angle, backward Angle, contact Angle lag, rolling Angle and dynamic contact Angle of materials on solid surface;
3. Continuous real-time research and process recording of absorption materials, and curve analysis of contact Angle changes with time;
4. Measurement of contact Angle of various special materials, such as powder, curved surface, superhydrophobic/superhydrophilic samples;
5. Test the contact Angle of the material immersed in the liquid by adhesive drop method;
6. Measurement of interfacial tension, polarity and dispersion components of various liquid surface by droplet method;
7. Calculate the Surface free energy and analyze its polar dispersion component;
8. Analyze the adherent work of liquid on solid surface to evaluate the uniformity and cleanliness of solid surface.Optical Contact Angle Tester Contact GoniometerG LR-SDC-100
Specifications
Host machine
Outsize550mm(L)*196mm(W)*485mm(H)
Weight11KG
Power220V / 60HZ
Light source system
Light sourceDense LED can adjust blue tone industrial grade cold light source
LifelongThe service life is more than 25,000 hours
Injection unit
InjectorDedicated precision syringe capacity 1000μL
DripManual rotary injection, drip precision can be achieved 0.2μL
Injection unit movementUp down 100mm; Left right 100mm
Acquisition system
CCDSONY imported high speed industrial chip with 25 frames /S and 130W pixels
Lens0.7-4.5 times hd industrial-grade continuous variable magnification microscope
Acquisition system adjustmentBefore and after 60 mm, view Angle adjustable (smooth inspect, look down, 360 ° rotating Angle of view, etc)
Sample station installation
Work Table size120mm*150mm
Maximum sample size10inch
Maximum sample sizeFront back move manual,stroke 60mm,accuracy 0.1mm
Left right move, manual,stroke 35mm,accuracy 0.1mm
Up down move, manual,stroke 80mm,accuracy0.1mm
Software
Contact Angle measurement range0-180°
Accuracy of contact Angle measurement±0.1°
Analyze software functions1,China's most advanced contact Angle measurement and analysis software automatic fitting method(One key automatic fitting,There is no manual error
)Include:Circle method,Ellipse/Oblique ellipse,LY,(Differential circle / Differential ellipse);
2,Dynamic contact Angle fitting (batch fitting of multiple images),include Wettability,(Video analysis);
  1. Surface energy;
  2. Adhesion work;
Optical Contact Angle Tester Contact GoniometerG LR-SDC-100Accord with national standard
1.GB/T 24368-2009(detection of hydrophobic pollutants on glass surface);
2.SY/ t5153-2007 (reservoir rock wettability measurement method);
ASTM D 724-99 (2003) (test method for wettability of paper surfaces);
4.ASTM d5946-2004 (measurement of the contact Angle between plastic film and water);
5.ISO15989 (measurement of water contact Angle of plastic film and thin plate corona treated film);

Optical Contact Angle Tester Contact Goniometerg Lr-Sdc-100

Optical Contact Angle Tester Contact Goniometerg Lr-Sdc-100

Optical Contact Angle Tester Contact Goniometerg Lr-Sdc-100

Optical Contact Angle Tester Contact Goniometerg Lr-Sdc-100

Optical Contact Angle Tester Contact Goniometerg Lr-Sdc-100